5. Measurement Functions and Ranges
DC Current Measuring
Range
40 µA
400 µA
4000 µA
40 mA
400 mA
10 A
- Maximum Input Current: 400 mA DC or 400 mA AC in the µA- and
mA-Range (Fuse 0.5 A), 10 A DC or AC in the 10 A-Range (Fuse 10
A)
AC Current Measuring
Range
40 µA
400 µA
4000 µA
40 mA
400 mA
10 A
- Maximum Input Current: 400 mA DC or 400 mA AC in the µA- and
mA-Range (Fuse 0.5 A), 10 A DC or AC in the 10 A-Range (Fuse 10
A)
- The given values apply for frequencies of 50 to 60 Hz
Resolution
0.01 µA
0.1 µA
1 µA
10 µA
100 µA
10 mA
Resolution
0.01 µA
0.1 µA
1 µA
10 µA
100 µA
10 mA
45
Accuracy
± 1 % v. M. ±3 St.
± 1.5 % v. M. ±3 St.
± 2.5 % v. M. ±5 St.
Accuracy
± 1.5 % v. M. ±5 St.
± 1.8 % v. M. ±5 St.
± 3.0 % v. M. ±7 St.