Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Features - FLAEM ELISIR Bedienungsanleitung

Gerät für aerosolterapie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
Elisir can be used with RHINO CLEAR Nasal wash

TECHNICAL FEATURES

Aerosol therapy unit
Mod. ELISIR F1000
Voltage:
230V ~ 50Hz 140VA
Fuse:
T 2A - 250V
In compliance
Dir. 93/42/EEC
with:
(EN 60 601-1/A2)
Approvals:
Max pressure:
Compressor air output:
Dimensions:
Weight:
Sound level (at 1 m):
Continuous use
In vitro characterization carried out at the Inamed Research GmbH & Co. KG on behalf of TÜV Rheinland Product Safety
GmbH – Germany in compliance with the new European Standard for aerosol therapy appliances, Standard EN 13544-
1. Further details are available upon request.
- MMAD:
- Breathable fraction < 5 µm (FPF):
Operating requirements:
Storage requirements:
Operating/storage atmospheric pressure: P min. 690 hPa; max. 1060 hPa
• The Manufacturer, the Retailer and the Importer are responsible for safety, reliability and performance only if: a) the
unit is used following the instructions for use; b) the electrical system of the premises where the appliance is used
is in conformity with current laws.
• Repairs should be performed by authorised personnel only. Unauthorised repairs will invalidate the warranty and
may represent a hazard to the user.
Disposal: In conformity with Directive 2002/96/EC on waste electrical and electronic equipment (WEEE), at the end
of its life the unit should be taken to an electrical appliance collection point for its environmentally friendly disposal.
SYMBOLS
Class II unit
B-type unit
Important safeguards
Warning: follow the operating instructions
Alternating current
Electromagnetic compatibility:
ELISIR unit is designed to meet the current requirements for electromagnetic compatibility. However if you suspect that the
unit is interfering with the operation of your TV, radio or other electrical unit, try relocating the unit until the interference
ceases. Alternatively try plugging the unit into a different power socket.
The Manufacturer reserves the right to make technical and functional changes to this product without prior notice.
115V ~ 60Hz 180VA
T 3A - 250V
0051
2.5 bar approx.
10 LPM approx.
20x30x10 cm
2.100 Kg
57 dB (A)
3,2 µm
73 %
temperature min. 10°C; max 40°C
RH air humidity min. 10%; max 95%
temperature min. -25°C; max 70°C
RH air humidity min. 10%; max 95%
220V ~ 60Hz 160VA
T 2A - 250V
RF6 PLUS nebuliser
Medication minimum capacity:
Medication maximum capacity:
Operating pressure (with neb.):
Max delivery
:
(1)
MMAD
:
(1) (2)
Particles % < 5 µm
:
(1) (2)
(1)
Average values measured with 0.9% saline solution in compliance with Flaem internal procedure.
(2)
Certified with TSI Aerosizer 3220 computerised laser system in compliance with Flaem
internal procedure.
Switch OFF
Switch ON
Do not use the unit when taking
a bath or shower
Latex Free
LATEX
7
100V ~ 50/60Hz
T 5A - 250V
2 ml
8 ml
0.9 bar approx.
0.42 ml/min approx.
1.53 µm
99 %

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis