Additional safety notices

If applicable, observe special work safety or
accident prevention regulations for the handling
of compressors and compressed air tools.
Ensure that the maximum permissible working
pressure specified in the Technical Data is not
exceeded.
Do not overload this tool – use this tool only
within the capacity range specified in the
Technical Data.
Use safe lubricants. Ensure sufficient ventila-
tion at the place of work. In case of increased
discharge:
check the compressed air tool and have it
repaired if necessary.
Do not use this tool if you are distracted. Be
alert, watch what you are doing and use com-
mon sense when operating a compressed air
tool. Do not use tools when you feel tired or are
under influence of drugs, alcohol, or medica-
tion. A moment of inattention when operating
the tool can result in serious personal injuries.
Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
Keep compressed air tools out of reach of
children.
Do not store outdoors or in damp environments
without protection.
Protect the compressed air tool, in particular the
compressed air connection and operating ele-
ments against dust and dirt.
GB │ IE │ NI
12 

Before use

NOTE
The compressed air tool may only be oper-
ated using cleaned, oil-atomised compressed
air and the maximum operating pressure of
6.3 bar must not be exceeded on the ap-
pliance. The compressor must be fitted with
a pressure reducer to regulate the working
pressure.
Wind the supplied Teflon tape
threaded connectors.

Fitting the connector nipple

Wrap the threads on the connector nipple
with the supplied Teflon tape
Screw the connector nipple
inlet
.

Lubrication

NOTE
Regular lubrication is particularly important
to avoid friction and corrosion damage.
We recommend using a suitable special oil
for compressed air tools (e.g. Liqui Moly
compressor oil).
Lubrication with mist oiler
A mist oiler (not supplied) continuously
and optimally lubricates the grinder as
a preparation stage after the pressure
reducer. A mist oiler releases fine drops
of oil into the air flow and it thereby
guarantees a regular lubrication.
Manual lubrication
If you do not have a mist oiler, lubricate
the tool before every use or longer work
sessions. Add 3–4 drops of pneumatic
oil into the connector nipple
around all
.
into the air
.