Program description

Semi automatic program mode (default setting):
DIP switch 1=OFF, 2=ON
15 - 50 cm
Switch on
Tap the ON/OFF icon or
approach the infrared sensor
(below the spout) with your
hand; this will cause the ON/
OFF icon to illuminate and
the water flow to start.
If your hands frequently leave the sensor range while washing your hands, for example,
causing the water flow to stop prematurely, you can extend the shut-off delay to 2 s.
When using an instantaneous water heater, the configured shut-off delay helps to minimi-
se the number of ignition processes.
DIP switch 6 ON = Extended shut-off delay – 2 s
DIP switch 6 OFF = Standard shut-off delay – 1 s (default setting).
OCEAN W7
User detection
When you step in front of the
wall fitting, the system will
detect you. The illuminating
icon begins to pulse slowly.
Switch off
Once you clear the sensor
range or after the configu-
red shut-off delay time (DIP
switch 6) has elapsed, the
water will stop.
You can also manually stop
the flow of water by tapping
the ON/OFF icon.
Safety flow arrest
After the configured water
arrest time has elapsed, the
water flow will automatically
stop to prevent unintentional
continuous activation.
SanTec OCEAN W7
Wall tap control
EN
Werkseinstellung:
ON
ON
OFF
OFF
1 2 3 4 5 6
ON
ON
OFF
OFF
1 2
3 4 5 6
ON
ON
OFF
OFF
1 2
3 4 5 6
ON
ON
OFF
OFF
1 2
3 4 5 6
ON
OFF
1
2
3 4 5 6
27