Program description

Fully automatic program mode (default setting):
DIP switch 1=ON, 2=ON
Switch on
As soon as you enter the
sensor range, the water flow
will start automatically.
(range control configurable
from 15–30 cm)
If your hands frequently leave the sensor range while washing your hands, for example,
!
causing the water flow to stop prematurely, you can extend the shut-off delay to 5 s.
When using an instantaneous water heater, the configured shut-off delay helps to minimi-
se the number of ignition processes.
DIP switch 6 ON = Extended shut-off delay – 5 s.
DIP switch 6 OFF = Standard shut-off delay – 2 s (default setting).
Switch off
Once you clear the sensor
range or after the configu-
red shut-off delay time has
elapsed, the water will stop.
(DIP switch 6)
Wall tap control
Werkseinstellung:
ON
OFF
1 2 3 4 5 6
ON
OFF
1
2 3 4 5 6
ON
OFF
1
2 3 4 5 6
Safety flow arrest
After the configured water
ON
arrest time has elapsed, the
OFF
1
2
water flow will automatically
stop to prevent unintentional
continuous activation.