Specifi cations
Operating voltage:
Power consumption:
Active range:
Close-Active range:
Flushing:
Flushing stop:
s - 60 s)
Stagnation rinse:
Continuous fl ow:
Cleaning stopp:
Flow rate:
Static pressure:
Water temperature:
Flow rate:
Water inlet:
Noise class:
Assembly
of fl ush-mounted box 47 mm
OCEAN W7
via power supply 230 V 50 Hz / 12 V=
Art.No. 117 899 - power supply for one control unit
Art.No. 113 792 - power supply for up to 5 control units
max. 3.5 W
Set to 50 cm by default (confi gurable from 15 - 50 cm)
4 - 5 cm
as long as user is in active range
set to 1 min by default (confi gurable from 10 s - 10 min, manual program: 10
for 10 s when not in use for 3–48 h (confi gurable, set to 48 h by default)
set to 1 min by default (confi gurable from 10 s - 10 min)
3 min (switchable)
0,05 - 0,6 MPa (0,5 - 6 bar)
max. 0,8 MPa (8 bar)
max. 70 °C (max. 80 °C for max. 10 min)
6 l/min (independent of pressure)
R 1/2" IG
I
Outlet middle to middle
12 - 15 cm
DN 15
Active range
15 - 50 cm confi gurable
12 V=
Wandarmatur
15°
SanTec OCEAN W7