Configuring the programs & functions
Regulator controls:
D.
Range control
for sensor area adjustment
preset to 50 cm
(configurable from 15–50 cm).
Sets the infrared sensor range
from 15–50 cm.
Note on range setting:
Most operating modes (depending on the DIP switch configuration) will stop the water flow as soon as you remove
your hands from the sensor area. In particular as regards shallow, large ceramic basins, the basin itself can cause the
sensor to trigger continuously. This is evidenced by the water flow continuing for a long time or the fitting triggering
on its own. In extreme cases, the fitting will trigger by itself, water will flow until the water arrest time has been
reached, and then the device will no longer trigger. If this happens, you need to reduce the sensor range. If the
range is too low, the infrared sensor may no longer be able to properly detect your hands. In most operating modes,
this will make it impossible to maintain a constant stream of water. In this case, increase the sensor range.
G. DIP switches:
Program activation – DIP switches 1 and 2:
Program
Semi automatic mode
Fully automatic mode
Manual mode
Function activation – DIP switches 3–6:
DIP switch
Function
3
Cleaning stop
4
Continuous flow
5
Stagnation rinse
6
Shut-off delay ON = 2 s / OFF
v
OCEAN W7
E.
Time control
for safety flow arrest preset to
1 min (configurable from 10 s
to 10 min).
Manual program mode: confi-
gurable from 10 s to 60 s.
After the configured maxi-
mum flow time has elapsed,
the water stops automatically.
DIP switch 1
OFF
1)
ON
OFF
1)
F.
Interval control
for stagnation rinse
preset to 48 h
(configurable from 3 h –
48 h).
Setting acc. to DIP switch 5 –
see page 32.
DIP switch 2
Description
ON
Page 27
ON
Page 28
OFF
Page 29
Description
Page 30
Page 31
Page 32
1)
= 1 s
Wall tap control
SanTec OCEAN W7
EN
21

Werbung