Herunterladen Inhalt Inhalt Diese Seite drucken

Select Charging Mode; Reset/Deleting Settings; Switching Between Modes 1, 2, 3 And 4; Mode 1 "6 V" (7.3 V/0.8 A) - ULTIMATE SPEED ULG 3.8 B1 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ULG 3.8 B1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
Remove the positive terminal clamp (red)
the charger from the positive terminal on the
battery.

Select charging mode

You can choose between different charging modes
for charging various batteries at different ambient
temperatures.
Unlike standard battery chargers, this appliance has
a special function for reusing an empty chargeable
battery or accu. You can recharge a completely dis-
charged battery/accu. A protection function against
incorrect connection and short circuiting ensures
safe charging. Due to the installed electronics, the
charger does not begin operation directly after
connecting the battery, but only starts after a
charging mode has been selected.
This prevents sparking, which often occurs when
connecting. In addition, the battery charger is con-
trolled by an internal MCU (micro-computer unit).

Reset/deleting settings

After connection to the power supply, the appli-
ance automatically returns to its initial state and
remains in Standby mode
Switching between modes 1, 2, 3
and 4
Press the MODE selection button
amount of times.
The appliance switches through the modes in the
following order: Standby ( ), Mode 1 (
2 ( ), Mode 3 (
), Mode 4 ( ) and then starts
the next cycle.
NOTE
If you press the MODE selection button
charging mode automatically switches to the next
mode and begins operation in that mode. If a
12 V battery is connected, Mode 1 ( ) is not
selectable. If a 6 V battery is connected, Mode
2 ( ) 3 (
) and 4 ( ) are not selectable. If
a battery is not disconnected from the charging
station after a full charge, the appliance remains
in trickle-charge mode, even if the user switches
over to another mode. This protects the fully
charged battery from being damaged.
ULG 3.8 B1
Mode 1 "6 V" (7.3 V/0.8 A)
of
This mode is suitable for charging 6 V lead-acid
batteries with a capacity below 14 Ah.
Press the selection button MODE
Mode 1 (
LED display
vate another process afterwards, the electronic
system will automatically activate together with
the LED display
process.
If the procedure runs without any problems,
the LED display
entire charging process, until the battery is fully
charged to 7.3 V/± 0.25 V. When the battery
is fully charged, the LED display
up and the LED display
The appliance now switches automatically into
trickle charging mode.
Mode 2 "12 V" (14.4 V/0.8 A)
This mode is suitable for charging 12 V lead-acid
batteries with a capacity below 14 Ah.
Press the MODE selection button
Mode 2 ( ). After doing so, the corresponding
LED display
vate another process afterwards, the electronic
system will automatically activate together with
the LED display
a corresponding
process.
If the procedure runs without any problems,
the LED display
), Mode
entire charging process, until the battery is fully
charged. When the battery is fully charged,
the LED display
display
The appliance now switches automatically into
, the
trickle charging mode.
Mode 3 "12 V" (14.4 V/3.8 A)
This mode is mainly used for charging 12 V lead-
acid batteries with a large capacity of more than
14 Ah under normal conditions.
Press the MODE selection button
Mode 3 (
process afterwards, the electronic system will
activate together with the LED display
and starts the charging process.
). After doing so, the corresponding
lights up. If you do not acti-
and starts the charging
remains on during the
goes out.
lights up. If you do not acti-
and starts the charging
remains on during the
lights up and the LED
goes out.
). If you do not activate another
, to activate
GB
MT
lights
, to activate
, to activate
29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis