Herunterladen Inhalt Inhalt Diese Seite drucken

First-Time Operation; Repair, Conversion Of Unit - AEG WSP 3510 N Gebrauchs- Und Montageanweisung

Wärmespeicher niedrig-baureihe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.6 First-time Operation

Short-circuit danger charging control unit
When measuring the voltage at the thermal relay contacts the charging control unit is destroyed
in the case of ground connection – slipping of the measuring peaks.
The display still lights "green"!
2.6.1 Function Test
Check the function of the fan for the storage unit by switching on the room temperature regula-
tor.
2.6.2 Charging
The units can be started without initial heating up after the function test. Charging takes place
either manually with the adjuster of the electronic charging control unit or automatically with the
available Elfamatic charging control unit.
During initial charging, the charging in kWh must be determined and compared with the
maximum permissible charging from the cold state specified in the "Technical Data". The deter-
mined charging may not exceed the maximum permissible charging duration from the cold state.
During initial charging, a smell may be produced, the room should therefore be adequately aired
(1.5 times air change, e.g. tilted windows). Initial charging in the bedroom should not take place
when sleeping in it if possible.

2.7 Repair, Conversion of Unit

Proceed according to these installation instructions as for the initial installation for re-installation
of a unit which has been dismantled for repairs or which was in operation somewhere else.
In these cases the following must be paid special attention: Parts of the thermal insulation at
which there are visible signs or damage or change which could impair the safety must be replaced
by new parts. The insulation must be tested and the rated consumption measured before commis-
sioning.
2.7.1 Conversion of the Unit
The instructions enclosed with the respective fitting set are applicable for conversions, additions
and installations.
2.8 Transfer
Explain the functions of the unit to the user. Draw his attention to the safety instructions in
particular.
Hand over the operating and installation instructions to the user.
WSP 5010 N
956 042 835
E-No.
4,16 4,58 5,00 4,87 5,41 5,95 6,50
3,75
5
7
10
259 kg
20200504
F-
No.
3/N/PE AC 400V 50Hz
X
kW
X
h
6
8
9
1/N/PE AC 230V 50Hz
kW
1,5
26 W
Made in Germany
Symbols of the rating plate
(Example WSP 5010 N)
Total weight
Charging
Discharging
Supplementary heater
Fan
For the Fitter
33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wsp 5010 n

Inhaltsverzeichnis