For the User

1. Operating Instructions

1.1 Technical Description

Storage heaters store electrically generated heat during low-cost electricity tariff periods
(depending on the electricity supply company, mainly during the night hours). This is then
discharged according to the desired room temperature as hot air by a fan and to a small extent
through the surface of the heater.

1.2 Operation

The heater operation takes place by means of the recessed operating knob at the top right of the
heater. By pushing the knob lightly, it will emerge for operation. After adjustment, the knob can be
pushed back into the heater. The knob can be recessed in any adjustment position.

1.2.1 Heat Storage

Heat Storage takes place automatically. The amount of residual heat from the previous day is
always taken into account when the heater is charged using the charge control.
Automatic Central Charge Control
The charge adjusting knob should always be set to MAX (fully clockwise), at least in rooms that are
in continuous use. If the heater charge in other, less-frequented rooms is required to be reduced,
turn the adjusting knob slightly anti-clockwise. Remember that the adjustment only makes itself
felt on the following day(s). Do not, therefore, make too abrupt changes.
The amount of heat stored in the complete installation is controlled by the Central Charge Control
(in the distributor panel). To adjust this, please refer to the Instruction Manual supplied with the
charge control.
Manual Control
If the heater is not connected to a Central Charge Control the amount of heater to be stored is
determined by adjusting the continuous-run manual charge knob on the heater as follows:
No storage: Knob fully left (anti-clockwise)
Full storage: Knob fully right (clockwise)
Once the set level of heat has been stored, the charge control switches off automatically.

1.2.2 Heat Discharge

The control of the heat discharge is by means of a room thermostat. Once the room temperature
falls below the set level, the fans in the storage heater are switched on and heat dissipated into
the room for such a period as is necessary to bring the temperature back up to the desired level.

1.2.3 Summer Operation

Turn the adjustment knobs both on the heater, and on the room thermostat to MIN (fully anti-
clockwise) during the summer months. Do not turn off the fuse or circuitbreaker to the central
charge control as this can desynchronise the charge control timer.