2.5 Unit Installation (fig. 3-14)
The storage heater must be secured by a wall or floor fixture (fig. 8) to meet the VDE standing
safety requirement.
The screws and plugs necessary for fixing the unit are not included in delivery. They must be
selected and provided by a qualified fitter depending on the respective wall material.
Wall fastening
There is a hole in the unit rear wall in the vicinity of the switching area through which a suitable
screw can be inserted for fixing to a sufficiently stable wall (fig. 8).
Before fixing the unit, make sure that the permissible minimum distances from adjacent objects
are kept.
Floor fastening
The unit is fixed to the floor by screwing the bottom of the unit to the floor through 4 9 mm holes
(see "Technical Data", page 9 for dimensions).
This type of fixture is only possible with the air outlet and inlet grilles and the fan drawer removed.
2.5.1 Unit Installation (fig. 3-6)
Draw the air inlet grille (6) at its underside towards you (the front) off the catch spring, and
release it out of the top catch by lifting it.
Loosen the air inlet grille (5) using both the quarter-turn caps and remove the grille (fig. 3).
Loosen the front wall (4) with 2 screws at the bottom (inside threaded holes), lift the front wall
slightly and remove (fig. 4). Loosen the inside front wall with 2 screws at the bottom and remove
(fig. 5).
Disassembly of the right side wall (3): Remove the rotary knob (a), screws (b1 and b2) on the side
wall (3), pull the side wall slightly to the side at the back (c), push forward, tilt to the side at the
top (d), lift and remove (fig. 6).
Feed the power cables and connecting cables for charging control unit and discharge control
unit through the opening in the unit rear wall (15) and connect according to section 2.5.2 (lay
connecting cable about 210 mm and shorten as required so that it does not obstruct the air
vents in the side wall);
Place the unit at the planned location and screw to the wall (or to the floor if floor fixing is
necessary).
Remove cover plate (10), cardboard inlays and operating button from inside (fig. 9). This must be
completely free of foreign bodies such as packing leftovers.
Check the thermal insulation in the unit for transportation damage and replace if necessary.
Insert the storage blocks (fig. 10 and 11)
The storage blocks are delivered packed separately.
Storage blocks with slight transportation damage may still be used. This does not impair the
function of the heater.
The heating elements (17) must be lifted slightly to insert the storage blocks (9) (fig. 10).
Place the first storage block with the heating element recess at the top some distance away from
the right thermal insulation under the heater and push to the right and rear thermal insulation.
The elongated holes form the heating channels.
When lifting the heating elements, make sure that the through holes in the side thermal insulation
are not widened by the heating elements.
Then push the cover plate (10) removed from the interior over the top storage blocks (fig. 12).
For the Fitter
29