Herunterladen Inhalt Inhalt Diese Seite drucken

AEG WSP 3510 N Gebrauchs- Und Montageanweisung Seite 29

Wärmespeicher niedrig-baureihe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Power adaptation according to rated charging time
By moving or removing bridges at the terminals, the output can be adapted to the rated charging
time specified by the electricity supply company.
Heating element model
Rated charging time
Connection variants (kW)
Model
WSP 3510 N
WSP 5010 N
7 h
100 % P
100 % P
Nenn
rated
(Serienverdrahtung)
(series wiring)
1
3
2
1
L3
N
3/N/PE ~ 50 Hz 400 V
8 h
91.6 % P
91,6 % P
Nenn
rated
2
3
2
1
L3
N
3/N/PE ~ 50 Hz 400 V
Unit rating plate
Observe the labelling on the rating plate and the circuit diagram!
After connecting electrically, the box corresponding to the connection rating and rated charging
time of the unit on the rating plate and the circuit diagram in these installation instructions
should be marked with a smear-proof ballpoint pen.
2.5.3 Unit Ready for Operation
Cleaning the unit (fig. 13 and 14)
The open unit must be cleaned after installation and insertion of the storage blocks.
The fans and the air guidance assembly must be removed for this.
Unscrew and remove the air guidance assembly (16)
Lift and remove the fan (18) after loosening (not removing) the screws at the front of the
support brackets (pay attention to cable laying!).
In some units, the discharge temperature control unit (19) including support plate must be
unscrewed.
Make sure the wires are not damaged when setting down the removed parts.
Clean the floor plate and fan (avoid damage to lamellas!). Then re-install the fans, possibly the
temperature limiter and the air guidance module (correct cable laying!).
Close the unit (fig. 15 and 16)
Hang in the inside front wall with thermal insulation swung forward slightly at an angle at the
top edge and screw at the bottom edge with 2 screws;
Hang in the right side wall at the bottom, tilt up, hang in at top and fix with screws (b1 and b2);
(reverse order see 2.5.1 – disassembly right side wall fig. 6)
Hang in front wall at top, swing to the heater at the bottom and fix with 2 screws (always use
the two inside threaded holes) (fig. 15);
Tighten the air inlet grille (5) with both the quarter-turn caps (fig. 16);
Hang the top edge of the air inlet grille in the lock screws at the air guidance assembly and then
press the bottom over the catch springs (fig. 16).
7h
8h
Œ

3.5
3.21
5.0
4.58
9 h
83,3 % P
83.3 % P
3
L2
L1
3
2
1
X1
L1
L3
L2
3/N/PE ~ 50 Hz 400 V
10 h
75 % P
75 % P
4
L2
L1
X1
3
2
1
L3
L2
L1
3/PE ~ 50 Hz 400 V
8h (series)
9h
10h
Ž

2.91
2.63
4.16
3.75
Nenn
rated
L3
L2
L1
X1
N
L3
L2
L1
Nenn
rated
L3
L2
L1
X1
L3
L2
L1
For the Fitter
6h (heating element fitting set)
5h
6h
7h
Œ

Ž
4.9
4.49
4.08
6.5
5.95
5.41
31

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wsp 5010 n

Inhaltsverzeichnis