Frequency "Hz" (electronic)
Range
≤9.999 Hz*
10.00 Hz - 99.99 Hz
100.0 Hz - 999.9 Hz
1.000 kHz - 9.999 kHz
10.00 kHz - 99.99 kHz
100.0 kHz - 999.9 kHz
1.000 MHz - 9.999 MHz
>10.00 MHz*
*The specified frequency range is 10.00 Hz - 10 MHz
Signal level (without direct voltage component):
≤1 MHz: 300 mV - 30 Vrms
>1 MHz - 10 MHz: 600 mV - 30 Vrms
600 V overload protection
Diode test
Test voltage
Approx. 3.0 V/DC
Overload protection: 600 V; Test voltage: 2 mA typ.
Acoustic continuity tester
Measurement range
600 Ω
≤10 Ω continuous tone; ≥100 Ω no tone
Overload protection: 600 V
Test voltage approx. 1 V
Test current 0.7 mA
Never exceed the maximum permitted input values. Never touch circuits or parts of circuits when
they may contain voltages greater than 33 V/ACrms or 70 V/DC! Danger of death!
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.001 MHz
0.01 MHz
Resolution
0.001 V
Resolution
0.1 Ω
Accuracy
Not specified
±(0.1% + 6)
Not specified