Proceed as follows to measure alternating currents (mA/µA
- Switch the DMM on and select "mA" or "µA" mode. Press "SELECT" to switch to AC mode. "AC" and "TRMS"
appear on the display. Press the "SELECT" button again to switch back to DC mode.
- The table shows the different modes and potential measurement ranges. Select the measurement range and cor-
responding measurement sockets.
Measurement mode
µA
mA
- Insert the red test lead into the mA µA measurement socket. Insert the black test lead into the COM measurement
socket.
- Connect the two measuring probes (de-energised) in series to the object that you want to measure (e.g. generator,
battery or circuit). The electrical circuit must be disconnected before you connect the probes.
- Reconnect the circuit. The measurement will appear on the display.
- After measuring, disconnect the circuit and remove the test leads from the measured object. Switch the DMM off.
58
Measurement range
0 - 6000 µA
0 - 600 mA
):
Measurement sockets
COM + mAµA
COM + mAµA