8.2.1

Voltage measurement

-
Select the desired function (V AC) or (V DC) by means of the rotary switch
8 of the BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the black safety measuring line to the COM jack J of the
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the red safety measuring line to the jack for V, Ω,
BENNING MM 1-1/ 1-2/ 1-3.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
BENNING MM 1-1/ 1-2/ 1-3.
See figure 2:
See figure 3:
8.2.2
Current measurement (BENNING MM 1-2/ 1-3)
-
Select the desired range and function (A AC) or (A DC) by means of the
rotary switch 8 of the BENNING MM 1-2/ 1-3.
-
Connect the black safety measuring line to the COM jack J of the BENNING
MM 1-2/ 1-3.
-
Connect the red safety measuring line to the jack for V, ,
to the jack for the 10 A range K (DC or AC currents up to 10 A) of the
BENNING MM 1-2/ 1-3.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
BENNING MM 1-2/ 1-3.
See figure 4:
See figure 5:
8.3 Resistance measurement
-
Select the desired function (Ω) by means of the rotary switch 8 of the
BENNING MM 1-1/ 1-2/ 1-3
-
Connect the black safety measuring line to the COM jack J of the
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the red safety measuring line to the jack for V, ,
BENNING MM 1-1/ 1-2/ 1-3.
-
Bring the safety measuring lines into contact with the measuring
points and read the measured value on the digital display  of the
BENNING MM 1-1/ 1-2/ 1-3.
See figure 6:
8.4 Diode test
-
Select the desired function (
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the black safety measuring line to the COM jack J of the
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the red safety measuring line to the jack for V, ,
BENNING MM 1-1/ 1-2/ 1-3.
-
Bring the safety measuring lines into contact with the diode connections
and read the measured value on the digital display  of the
BENNING MM 1-1/ 1-2/ 1-3.
-
For a standard Si diode applied in conduction direction, a conduction voltage
between 0.400 V and 0.900 V is displayed. „000" indicates a short-circuit
inside the diode, „OL" indicates an interruption inside the diode.
-
For a diode applied in reverse direction, „OL" is indicated. If the diode is
defective, „000" or other values are indicated.
See figure 7:
8.5 Continuity test with buzzer
-
Select the desired function (
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the black safety measuring line to the COM jack J of the
BENNING MM 1-1/ 1-2/ 1-3.
-
Connect the red safety measuring line to the jack for V, ,
BENNING MM 1-1/ 1-2/ 1-3.
-
Bring the safety measuring lines into contact with the measuring points. If the
line resistance between the COM jack J and the jack for V, ,
below 25 , the integrated buzzer of the BENNING MM 1-1/ 1-2/ 1-3 sounds.
See figure 8:
11/ 2007
DC voltage measurement
AC voltage measurement
DC current measurement (BENNING MM 1-2/ 1-3)
AC current measurement (BENNING MM 1-2/ 1-3)
Resistance measurement
) by means of the rotary switch 8 of the
Diode test
) by means of the rotary switch 8 of the
Continuity test with buzzer
BENNING MM 1‑1/ 1‑2/ 1‑3
, Hz 9 of the
, Hz 9 or
, Hz 9 of the
, Hz 9 of the
, Hz 9 of the
, Hz 9 falls
18