4.6. AC Power Input Setting

The waveform generator adopt 110V/220V AC power source. Users should regulate the
voltage scale of the Power Switch according to the standards in their own country (see
Figure 0-2 / 8 on page 61) at the rear panel and use an appropriate fuse.
Voltage
Fuse
110V
125 V, F4AL
220V
250 V, F2AL
To change the voltage scale of the instrument, do the following steps:
1.
Turn off the power button at the front panel and remove the power cord.
2.
Check if the fuse installed before leaving factory (250 V, F2AL) can match with
the selected voltage scale; if not, pry the cover open using a straight screwdriver
(Figure 0-2 / 7 on page 61) change the fuse.
3.
Regulate the Power Switch to the desired voltage scale.

4.7. Power On

(1) Connect the instrument to the AC supply using the supplied power cord.
Warning:
To avoid electric shock, the instrument must be grounded properly.
(2) Press down the power button at the front panel, the screen shows the boot
screen.