Herunterladen Inhalt Inhalt Diese Seite drucken

Specification And Ordering Information; Technical Data - Camille Bauer KINAX WT 707 Betriebsanleitung

Messumformer für drehwinkel
Vorschau ausblenden Andere Handbücher für KINAX WT 707:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Specification and ordering information

Significance of digits 1. to 7.
Order Code 707 –
1. Version of the transmitter
Standard,
Measuring output non-intrinsically safe
EEx ia IIC T6,
ATEX,
Measuring output intrinsically safe
Ex ia IIC T6,
FTZU (Czech republic),
Measuring output intrinsically safe
2. Sense of rotation
Calibrated for sense of rotation clockwise
Calibrated for sense of rot. counterclockwise
V characteristic
Calibrated for both senses of rotation
3. Measuring range (measuring input)
°
0 ... 10
°
0 ... 30
°
0 ... 60
°
0 ... 90
°
0 ... 180
°
0 ... 270
Non-standard 0...≥ 5 to 0...< 270
V characteristic
4. Output signal (measuring output)
0 ... 1 mA, 3 or 4-wire connection
0 ... 5 mA, 3 or 4-wire connection
0 ... 10 mA, 3 or 4-wire connection
4 ... 20 mA, 2-wire connection
or
0 ... 20 mA, 3 or 4-wire connection
4 ... 20 mA, 3 or 4-wire connection
0 ... 20 mA, 4-wire connection
Non-standard, 3 or 4-wire connection
0 ... > 1.00 to 0 ... < 20 mA

5. Technical data

Measuring input
0...≥ 5 to 0... ≤ 270
Measuring ranges:
(without gear)
Preferred ranges
0...10, 0...30, 0...60, 0...90,
0...180 or 0...270
0...≥ 10
(with additional gear)
Measuring output
Output variable I
:
Load-independent DC current,
A
proportional to the input angle
22
1
2
6
1
2
3
4
1
2
3
4
5
6
°
9
A
A
B
C
D
E
F
Z
°
°
° to 0...1200 turns
5. Power supply
24 ... 60 V DC/AC,
with electric isolation
85 ... 230 V DC/AC,
with electric isolation
12 ... 33 V DC,
without electric isolation
12 ... 30 V DC (Ex),
without electric isolation
6. Mounting mode
Without foot, without flange
With foot (mounted)
With flange (mounted)
7. Material of transmitter rear cover /
Routing of connecting cable
Plastic / connector
less cable plug, socket mounted
for cable routed to the rear
Plastic / connector
less cable plug, socket mounted
for cable routed to the front
Plastic / connector
with cable plug, cable routed
to the rear
Plastic / connector
with cable plug, cable routed
to the front
Metal / screw terminals and cable glands
Note
The remaining order code digits concern special
features, e.g. the ancillary gear for extending the
measuring ranges.
Standard ranges:
0...1 mA, 3 or 4-wire connection
0...5 mA, 3 or 4-wire connection
0...10 mA, 3 or 4-wire connection
4...20 mA, 2 wire connection
or
0...20 mA, 3 or 4-wire connection
adjustable with potentiometer
4...20 mA, 3 or 4-wire connection
0...20 mA, 4-wire connection
Non-standard ranges: 0...> 1.00 to 0...< 20 mA
3 or 4-wire connection
1
2
A
B
0
1
2
1
2
3
4
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis