Assignment for connector 2:
Rotational speed output signal (optional).
Connector
Device plug
2
5
4
3
8
1
7
6
Top view
1)
RS-422 complementary signals; with cable lengths exceeding 10 m, we recommend
using a termination resistor of R = 120 ohms.
Assignment for connector 3:
Supply voltage and voltage output signal.
Connector
Device plug
6
1
5
7
2
3
4
Top view
Assignment for connector 4:
TMC - only for connection to the TIM 40 Torque Interface Module within HBM.
A3452-4.0 en/de
Assignment
pin
Rotational speed measurement signal
1
(pulse string, 5 V; 0)
2
Not in use
Rotational speed measurement signal
3
(pulse string, 5 V; 90 phase shifted)
4
Not in use
5
Not in use
Rotational speed measurement signal
6
(pulse string, 5 V; 0)
Rotational speed measurement signal
7
(pulse string, 5 V; 90 phase shifted)
8
Supply voltage zero
Shielding connected to housing ground
Assignment
pin
1
Torque measurement signal (voltage output; 0 V
2
Supply voltage 0 V;
Supply voltage 18 V  30 V DC
3
Torque measurement signal (voltage output; "10 V)
4
5
Not in use
Shunt signal trigger 5 V  30 V
6
7
Shunt signal 0 V;
Shielding connected to housing ground
1)
1)
1)
1)
)
27