Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; General, Interface, Electrical And Mechanical Parameters - Kübler IS60 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Technical data

3.1 General, interface, electrical an mechanical parameters
General parameters
Measurement axes
Measurement ranges
Resolution
Calibration accuracy (at 25°C)
Linearity deviation
Temperature coefficient (zero point)
Limit frequency
Sample rate
Operating temperature
Mechanical parameters
Interface
Bit rate
Functions
Electrical parameters
Power supply voltage
Current consumption (without load)
1 (0-360°) or 2 (X/Y)
±10° / ±45° / ± 60° / 0-360°
0,05° / 0,1° / 0,1° / 0,1°
±0,1° (zero point and end values)
max. ±0,2° / ±0,3° / ±0,4° / ±0,4°
typ ±0,008°/K
Type 20 Hz, 2nd. order (no digital filter) /
0,3...25 Hz, 8nd. order (with digital filter)
100 Hz
-40...+80°C
CANopen, per CIA DS 301,
profile per CIA DSP-410
10 kBit/s, 20 kBit/s, 50 kBit/s, 125 kBit/s,
250 kBit/s, 500 kBit/s, 800 kBit/s, 1 MBit/s
TPDO (RTR, cyclic, event-driven, synchronized),
parameterization per SDO and object register,
digital filter (Butterworth Lowpass, 8th order),
SYNC Consumer,
EMCY Producer, output and control of internal
device temperature (±2.0 K accuracy), failure
control with the help of Heartbeat or Nodeguar-
ding / Lifeguarding
10...30 VDC (The inclinometer must be supplied
with the help of a car battery or a safety-low vol-
tage (SELV) with limited power.)
40...105 mA
6

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis