Shutting down

 Turn off the appliance.
 Empty the full reservoir (refer to chapter
"Empty reservoir").
 Rinse the reservoir thoroughly with
clear water.
 Remove the accessories from the appli-
ance after each use and disassemble
the hose, nozzle and extension pipes.
Note: Possibly remaining water can
drip out, therefore you should place
these into the shower or bathtub.
 Flush the accessories separately under
runningn water and let air dry.
 Clean the foam filter under running wa-
ter; let it dry before reinserting it.
 Leave the appliance open to let it dry.
 Storing the appliance. Store the ac-
cessories on the appliance and store in
dry rooms.

Maintenance and Care

Risk of injury
Always switch off the appliance and pull out
the mains plug before care and mainte-
nance work.
Cleaning the device
With an uneven spray jet.
Illustration
 Loosen nozzle attachment and pull out,
clean or replace spray nozzle.
Clean the sieve in the fresh water
reservoir
1 x year or as needed.
Illustration
 Turn the lock and loosen it. Take out
the sieve and rinse it with water.
No water exiting from nozzle
 Fill up fresh water reservoir.
 Check the fresh water reservoir for cor-
rect fit.
 Detergent pump defective, contact Cus-
tomer Service.
Spray stream uneven
 Clean the spray nozzle of the spray ex
floor nozzle.
Insufficient vacuum performance
 Close the surrounding air separator at
the handle.
See diagram 11
 Accessories, suction hose or suction
tubes are clogged, please remove the
obstruction.
 Filter bag is full, insert a new filter bag
(for the order no. please see the spare
parts list at the end of the present in-
structions).
 Cleaning the foam filter
Detergent pump noisy
 Fill up fresh water reservoir.
Appliance is not running
 Plug in the main plug.
 The overheat alarm has been triggered,
please allow appliance to cool down.