Reflect Mount using Spacer Bar

The spacer bar eliminates manual spacing measurements and provides rigidity for mounting
the sensors while maintaining axial alignment. Refer to Programming the Flowmeter
(Page 22) before proceeding.
1. Perform all required menu steps taking note of the sensor model and size designation. The
2. Prepare the pipe surface area where the sensors will be mounted. Degrease the surface
FST020 IP65 NEMA 4X
Operating Instructions, 07/2010, A5E03086489-01
transmitter then issues the number index and prompts you to press <ENTER> to finish the
sensor install routine. Stop at this point.
Note
Note the number index value displayed in the [Install Xdcr] menu. You will use this index
to properly space the sensors. Check to ensure that you have a matched set of sensors.
They both should have the same S/N number but marked with either an "A" or "B" (e.g.,
19256A and 19256B).
and remove any grit, corrosion, rust, loose paint, etc.
Note
Before beginning refer to the Reflect Mount sensor installation diagram below.
Optional: On larger pipes, multiple
lengths of straps can be linked together
to surround pipe
Mounting Strap positioned around
Mounting Frame
Sensor shown in the 9 o'clock position on
pipe
Mounting Frame
Figure 2-3
Reflect Mount with Mounting Frames and Spacer Bar
2.3 Installing the Sensor
Space Bar Platform & Clamping Screw
Space Bar (Front View)
Metal Post
Mounting Strap Adjusting Screw
Installing/Mounting
11