Herunterladen Inhalt Inhalt Diese Seite drucken

Reflect Mount - Siemens SITRANS F series Betriebsanleitung

Ultraschall-durchflussmessgeräte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

● Mounting Straps
● Spacer Bar
● Mounting Guide (for Direct Mount)
● Ultrasonic coupling compound
● Sensors (matched set)
3.5.2

Reflect Mount

Reflect Mount - Sensor Installation using Mounting Frames and Spacer Bar
1. After receiving the spacing index from the Installation Menu, prepare the pipe surface
2. Degrease the surface and remove any grit, corrosion, rust, loose paint, etc.
Before beginning refer to the Reflect Mount Installation diagram example below.
Figure 3-8
Note
Minimum Ltn 18 mm (0.75 in).
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 07/2014, A5E03086486-AD
area where the sensors will be mounted.
Optional: On larger pipes, multiple lengths
of straps can be linked together to
surround pipe
Mounting Strap positioned around
Mounting Frame
Sensor shown in the 9 o'clock position on
pipe
Mounting Frame
Reflect Mount with Mounting Frames and Spacer Bar
Space Bar Platform & Clamping Screw
Space Bar (Front View)
Metal Post
Mounting Strap Adjusting Screw
Connecting
3.5 Sensor Installation
39

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis