PUTTING THE SYSTEM INTO OPERATION
Note: The "Standard" column contains the values the individual parameters contain when the control unit is delivered.
Table 1. HA (Lifting stations)
1
Run-down time 0
Switch-on
delay
0
ON 1
140
OFF 1
130
LED-display
POWER POWER ALARM ALARM LEVEL
Tabelle 1PS (Pumpstation)
1
Run-down time 0
Switch-on
delay
0
ON 1
450
OFF 1
180
LED-display
POWER POWER ALARM ALARM LEVEL
How do I access the parameter setting mode?
Keep the "Alarm" and "Pump" keys pressed simultaneously
for 5 seconds
→ an acoustic signal is given and the POWER LED flashes
slowly, you are in the first line (= run-on time)
→ the subsequent permanent flashing of the LEDs shows
which column you are in (which value is set), compare with
the above table
Note: The parameter setting mode is quit automatically after
2 minutes without a key being pressed.
Settings can be made as follows:
How can I change the line?
Keep the "Alarm" and "Pump" keys pressed simultaneously
again for 5 seconds
→ an acoustic signal sounds and the line is indicated by the
LED combination lighting up once
→ permanent flashing of the LEDs shows which column you
are in (which value is set), compare with the above table
Example video on Youtube under the link http://youtu.be/Ud9PAK3B3a8
2017/10
2
3
4
1
2
3
1
2
3
150
160
170
135
140
145
ALARM
LEVEL
2
3
4
1
2
3
1
2
3
530
500
520
200
220
240
ALARM
LEVEL
5
6
7
4
5
6
4
5
6
180
200
190
150
155
160
LEVEL
PUMP
PUMP
5
6
7
4
5
6
4
5
6
540
550
600
260
280
300
LEVEL
PUMP
PUMP
How can I change the column (change the value)?
Press the "Alarm" key once and you will move on to the next
column (shown by changed LED signals)
→ permanent flashing of the LEDs shows which column you
are in (which value is set), compare with the above table
How do I save my setting?
Press the "Pump" key once
→ an acoustic signal sounds (value has been changed)
Note: Set-up mode is not quit by simply pressing the "Pump"
key
How do I leave the parameter setting mode?
First possibility:
If the setting is to be saved: Press the
"Pump" key for 3 seconds
Second possibility: If the setting is not to be saved: Do not
press any key for 2 minutes
→ an acoustic signal sounds and parameter setting mode has
been quit.
43/168
Unit
Standard
1
Seconds
1
Seconds
Mono 180 / Duo 200
mmH 2 O
mmH 2 O
160
Unit
Standard
1
Seconds
Seconds
1
530
mmH 2 O
220
mmH 2 O