Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
US
• Do not use solvents and cleaning agents based on halogenized
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
6.4.2 Additional Information on the Electronic
Pressure Gauge
The electronic pressure gauge has passed a design examination. It has
been developed, constructed and manufactured in accordance with the
EU directive 94/9EU. It has been classified according to Ex ia IICT4 Ga or
Ex ia IICT4 Gb. It may be used and stored in the explosive zones 1 and
2 up to 60°C ambient temperature. Inspection authority: KEMA 05 ATEX
1090 X.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery replacement in explosive areas!
• Removal of the front cover of the pressure display!
• Installation of a battery other than the CR 1632 Renata!
When exchanging the battery, it is recommended to also replace the
sealing of the battery compartment!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
482
Danger! Risk of explosion!
Danger! Risk of explosion!
Danger! Risk of explosion!
Information!