Malfunction
No function of round/
flat fan control - control
knob can still be turned
Round/flat fan control
cannot be regulated
Spray gun does not
shut-off air
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Black digital display
Material leaks from be-
hind the paint needle
sealing
490
Cause
Air distribution ring has
not been positioned in
correct location (pin is
not located in the drill-
ings) or damaged
Regulation valve dirty
Clogged air piston seat
or worn air piston
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long
Unsuitable cleaning
solutions
Spray gun was im-
mersed in cleaning
solution for too long.
Wrong positioning of
the spray gun inside
the gun washing ma-
chine
Defective or missing
paint needle sealing
Clogged or damaged
paint needle
Corrective action
Replace air distribution
ring making sure it has
been positioned cor-
rectly when inserting it,
chapter 9.2
Remove round/flat fan
control, repair or re-
place it, chapter 9.7
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
Cleaning, observe
chapter 8, get a re-
placement spray gun
body.
Cleaning, observe
chapter 8, get a re-
placement digital unit.
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3