7.3.3

Metering settings

7.3.3.1 Setting the pre-metering time

The time is set in seconds.
To set the pre-metering time, proceed as follows:
1. Activate the DEFINE METERING SETTINGS menu.
2. Press the ↵ key.
3. Starting with the currently highlighted digit, enter the required value with the
The next digit can be selected with the ↵ key.
The time can be set to a value from 0 to 9999 sec at intervals of 1 sec.
4. Press the NEXT key to confirm.

7.3.3.2 Setting the pre-metering delay time

A "delay time can be set for the pre-metering" (=delayed start of pre-metering) in order to
prevent a metering of detergent before a minimum filling level is reached in the wash tank.
The time is set in seconds.
To set the pre-metering delay time, proceed as follows:
1. Activate the DEFINE METERING SETTINGS menu.
2. Press the ↵ key.
3. Press NEXT key.
4. Starting with the currently highlighted digit, enter the required value with the
The next digit can be selected with the ↵ key.
The time can be set to a value from 0 to 9999 sec at intervals of 1 sec.
5. Press the NEXT key to confirm.

7.3.3.3 Setting the concentration of SP1 and SP2

The rated value is set in mS/cm.
To set the rated value, proceed as follows:
1. Activate the DEFINE METERING SETTINGS menu.
2. Press the ↵ key.
3. Scroll with the NEXT key until the next menu is displayed.
4. Enter the rated value with the
The rated value can be set to a value between OFF and 200mS/cm.
Between 0.1 – 19.9 mS/cm, at an interval of 0.1 mS/cm
and, from 20 – 200 mS/cm, at an interval of 1 mS/cm.
5. Press the NEXT key to confirm.