Circuit breaker connection

Check that polarity is correct. Incorrect polarity will de-
stroy the electronics / control unit.
Screw on fuse holder (2) with provided cable between positive
terminal of battery and circuit breaker (3) (9±1 Nm).
Route 1 cable to control unit (4) from circuit breaker (3) and
screw to positive terminal of control unit.
Screw negative cable from battery (1) to negative terminal of
control unit (4).
1
4
Fig. 27

Connecting the drive motors

The data and motor cables must be routed together in such a
way that they cannot be torn off or damaged.
The cables may be shortened. Please pay attention to
different ring eyelet sizes.
Release the cover of the control unit by applying lateral pres-
sure to the latching lugs, and clamp the cables as shown in
the connecting diagram (red = positive, black = negative).
Please ensure that the connections are made properly. (Torque
M5 = 3.5 Nm / M6 = 6.0 Nm)

Connecting the battery

Liquid electrolyte batteries must be installed in a separate box
with ventilation leading to the outside. The fuse in the positive
lead must be connected outside the box. A separate box is
not required for gel or AGM batteries. Pay attention to the bat-
tery manufacturer's installation instructions.
The outgoing lines from the terminals must be routed with a
gap between them until after the fuse in the positive lead.
-
+
Fig. 28
3
2
9±1 Nm
-
+
Route the battery connector cables (only use the original
Truma cables supplied) to the control unit and attach them
securely using the clips and screws provided.
The battery connector cables must not be extended.
They must be routed separately from the motor cables,
and must not run over the control unit.
Route battery connector cables so that they do not chafe (par-
ticularly at leadthroughs through metal panels). Use suitable
protective leadthrough bushing to prevent damage to cables.
Connect battery connector cables to the existing battery ter-
minals (red = positive, black = negative).
Incorrect polarity will destroy the electronics / control
unit
The connection to the control unit (as per the connecting dia-
gram) must be made in the order: nut, battery connection ring
eyelet, nut (torque M6 = 6.0 Nm).
Connect fuse in the positive lead (150 A) near the positive
terminal.

Connecting the safety socket

Route the 2-wire cable provided (9 m or 10 m) with the flat
connectors through the socket holder (g) and the rubber
sleeve (h).
If necessary, open cover and push socket connection out of
socket housing (i).
Connect 2-wire cable with flat connectors to micro switch.
RD / BK
Fig. 29
If necessary, insert socket connector back into socket
housing (i).
Screw socket housing (i) to socket holder (g) using 3 sheet
metal screws (j). (Several positions are possible by selecting
the mounting holes at the socket holder and rotating the rub-
ber seal)
BK