Overview
Technical Data
Power graphs
Burner power min.-max.
Regulation range
Gas flow pressure
Gas valve assembly module
Fuel
Control and safety unit/flame monitor
Burner motor
Power consumption
Operation
Protection level
Ignition transformer
Air flap servomotor
Air pressure switch
Blast tube diameter x Insertion depth mm
Weight
CE Mark
Testing
Sound level conforms to VDI2715 dB(A)
Max. ambient temperature
Oil pump motor
Fuel-oil pump
Hose conduits
* The control ratio is a medium value and may change according to installation conditions.
Note on type designation:
G
= Natural gas
L
= Fuel oil EL
GL 06.1200 DUO PLUS
daPa
120
100
80
60
40
20
0
200
500
800
1100 1400 1700
230
1200
Power graphs
Boiler efficiency should be taken
into consideration when selecting
the burner.
Power graph indicates burner power
dependent on furnace pressure. They
correspond to the maximum EN
676-compliant values, as measured at
the test combustion chamber.
28
GL 06.1200 DUO PLUS
300 - 1200
kW
1 : 3/1 : 2 *
Gas/Oil
mbar
Natural gas (LL, E) H
2800 min
kg
1312 BM 3426
78
Between system and oil pressure pump: 2 x L1500; M16x1.5 - R1/2
Between oil pressure pump and burner head: 1x L1300; M14x1.5 - M14x1.5
06
= Size
1200 = Power rating
DUO PLUS = modulating operation
GL 06.1600 DUO PLUS
mbar
daPa
12
120
10
100
8
80
6
60
4
40
2
20
0
0
kW
200
300
Calculation of burner power:
Q
Q
= Burner power (kW)
F
Q
= Boiler rated power (kW)
N
h K = Boiler efficiency (%)
06/2006 - Art. Nr. 13 018 118B
GL 06.1600 DUO PLUS
300 - 1600
1 : 3/1 : 2 *
20 - 50- 100
MBVEF 412/MBVEF 420/VGD20 Rp2/VGD40 DN65
= 8.83 - 10.35 kWh/m
i
Fuel-oil EL conforming to country regulations
LFL 1.333
-1
, 230/400 V, 50 Hz, 2.2 kW
2840 W
IP54
EBI-M; 2 x 7.5 kV
SQM 50. 481
LGW 10 A 2
227 x 270 (KN)/370 (KM)/470 (KL)
in total 130 kg
1312 BM 3427
In accordance with EN 676; Emission class 3 for gas operation
In accordance with EN 267; Emission class 1 for oil operation
79
60° C
0.45 kW; 2800 min
AJ6 CC1004 3P; 290l/h
mbar
12
10
8
6
4
2
0
500
800
1100 1400 1700
kW
1600
Q
N
=
F
h K
GL 06.2100 DUO PLUS
480 - 2050
1 : 3/1 : 2 *
3
or propane gas (F) H
= 25.89 kWh/m
i
-1
2800 min
, 230/400 V, 50 Hz, 2.7 kW
3380 W
1312 BM 3428
81
-1
; 230 V
KN
= Normal burner head length
KM
= Medium burner head length
KL
= Long burner head length
GL 06.2100 DUO PLUS
daPa
120
100
80
60
40
20
0
480
200
500
800 1100 1400 1700 2000
3
mbar
12
10
8
6
4
2
0
2050
kW