Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - STEINEL IS 2180-5 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für IS 2180-5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Wiring examples
1. Light without neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1-4 x 100 W fi lament bulbs
2) Service load, light of 1000 W max. (see Technical specifi cations)
3) IS 2180-5 connection terminals
4) Indoor switch
5) Indoor series switch, manual, automatic
6) Indoor double-throw switch, automatic, permanent light ON
Operation/Maintenance
The Infrared Sensor is suit-
ditions may affect the way
able for switching light ON
the motion detector works.
and OFF automatically. The
Strong gusts of wind, snow,
unit is not suitable for spe-
rain or hail may cause the
cial burglary alarm systems
light to come ON when it
since it lacks the tampering
is not wanted because the
protection prescribed for
sensor is unable to distin-
this purpose. Weather con-
guish sudden changes of
20
2. Light with neutral conductor
4. Connection to double-throw switch
for permanent light ON and automatic
operation
Setting I: automatic operation
Setting II: manual operation for permanent
light ON.
Important: the unit cannot be switched OFF,
but operated only at settings I and II.
temperature from sources
of heat. The detector lens
may be cleaned with a
damp cloth it it gets dirty
(do not use cleaning
agents).

Troubleshooting

Malfunction
Cause
a
IS 2180-5
Fuse faulty; not switched
without power
ON
a
Short circuit
a
Mains switch OFF
a
IS 2180-5
Twilight control set to
will not switch ON
nighttime mode during
daytime operation
a
Bulb faulty
a
Mains power switch OFF
a
Fuse faulty
a
Detection zone not
properly targeted
a
IS 2180-5
Continuous movement
will not switch OFF
in the detection zone
a
Light is in detection zone
and keeps switching
ON as a result of
temperature change
a
Set to continuous
operation by indoor
series switch
a
IS 2180-5 keeps
Light is in detection zone
switching ON/OFF
a
Animals moving in
detection zone
a
Heat source (e.g.
extractor hood outlet) in
detection zone
a
IS 2180-5 switches ON
Wind is moving trees and
when it should not
bushes in the detection
zone
a
Cars in the street are
being detected
a
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans or
open windows
Remedy
a
Renew fuse, switch
ON mains power switch,
check wiring with voltage
tester
a
Check connections
a
Switch ON
a
Adjust setting
a
Change light bulb
a
Switch ON
a
Renew fuse, check
connection if necessary
a
Re-adjust
a
Check detection zone
and re-adjust if
necessary or fi t shrouds
a
Re-adjust zone or apply
shroud
a
Set series switch to
automatic mode
a
Adjust detection zone
or fi t shrouds, increase
distance
a
Adjust detection zone or
fi t shrouds
a
Adjust detection zone or
fi t shrouds
a
Blank off sections using
shrouds
a
Blank off sections using
shrouds
a
Adjust detection zone or
change site of installation
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis