b) Connect service lead
tor. Connect the protective-
The service supply lead
earth conductor to the earth
to the light is also a 2 to
contact (
3-core cable. The light unit's
7. Screw on housing and
live conductor must be
close again.
connected to the terminal
8. Fit lens (set reach to
marked L'. The service lead
either 8 m or 20 m max),
neutral conductor must be
see 'Reach setting' section.
connected to the terminal
9. Select time
marked N together with the
threshold setting
mains lead neutral conduc-
'Functions' section).
Installation using corner wall mount
Functions
Once you have connected
into operation. Two setting
the unit to the mains power
controls are concealed
supply, closed the housing
behind the front cover
and fi tted the lens, you are
ready to put the system
Switch-off delay
(time setting)
The chosen light ON time
can be varied continuously
from approx. 5 sec. to a
maximum of 15 min. Turning
the adjustment screw fully
anti-clockwise selects the
shortest time of approx.
5 sec. – 15. min.
Twilight setting
(response threshold)
The chosen detector re-
sponse threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
Turning the adjustment
screw fully anti-clockwise
selects daylight operation
2 – 2000 lux
at approx. 2000 lux. Turning
16
10. Locate front cover
and fi t security screw
).
protect cover from unau-
thorised removal.
Important: Reversing the
connections may result in
damage to the unit.
and light
(see
The corner wall mount
enclosed with the unit pro-
vides a convenient means
of installing the IS 2180-5
to internal and external
corners. Use the corner wall
holder as a template for
drilling the hole. This way,
you will drill the hole at the
right angle, allowing you to
fi t the wall mount with ease.
Important: Only carry out
time and light threshold
.
settings with the lens fi tted.
5 sec., turning the adjust-
ment screw fully clockwise
the longest time of approx.
15 min. The shortest time
setting is recommended
for setting the detection
zone and performing the
walk test.
the adjustment screw fully
clockwise selects twilight
operation at approx. 2 lux.
The adjustment screw must
be turned fully anti-clock-
wise for setting the detec-
tion zone and performing
the walk test in daylight.
Continuous illumination (manual override)
to
If a mains switch is installed
in the mains supply lead,
the light is capable of the
1 x OFF/ON
2 x OFF/ON
following functions in addi-
Important:
tion to the simple ON/OFF
The switch should be actu-
function.
ated in rapid succession
(in the 0.5–1 sec. range)
Sensor operation
1) Switch light on:
Actuate switch twice
1 x OFF and ON.
Light will stay ON for the
period selected.
2) Switch light OFF:
Actuate switch twice
1 x OFF and ON. Light
will switch OFF or go into
5 sec. – 15 min.
sensor operation mode.
3) Continuous illumination
(manual override):
Actuate switch (2 x OFF
and ON). Light will be set to
continuous illumination for
4 hours (LED - under the
lens - is lit), then automatic-
ally returns to sensor oper-
ation (LED OFF).
The light can also be
switched OFF during the
4 hours
4-hour period of continuous
illumination by switching
it OFF and then ON again.
This will return the light to
sensor operation.