Herunterladen Inhalt Inhalt Diese Seite drucken

Power Supply Unit - Bosch KTS 560 Originalbetriebsanleitung

Modul für die steuergeräte-diagnose
Vorschau ausblenden Andere Handbücher für KTS 560:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
7.3.2
AC and effective-value measurement
(CH1 and CH2)
1)
Property
AC frequency range
Measuring range
AC accuracy at 100 Hz
RMS accuracy at ≤ 10 kHz
Resolution
The measuring ranges in measurement modes "U" and "I" are
1)
given as peak-to-peak values. Consequently, the digital display
box is "grayed out" if the set measuring range is briefly exceeded
(overload).
7.3.3
Resistance measurement (CH1)
Property
Value/range
Measuring range
100 Ω — 1 MΩ
Accuracy up to 200 KΩ
±1.25 % of measured value
plus ±0.25 % of measuring range
Accuracy up to 1 MΩ
±2 % of measured value
plus ±0.25 % of measuring range
Resolution
0.1 Ω — 1000 Ω
(depending on measuring range)
Input resistance
> 9 MΩ
7.3.4
Current measurement (CH1 and CH2) with
100 A / 600 A current measuring clip (special
accessory)
Measurement up to
Measuring range
100 A
20 A, 50 A, 100 A
600 A
200 A, 500 A, 600 A
7.3.5
Continuity tester (CH1)
Property
Value/range
Measurement current
2 mA
No-load voltage
≤ 5 V
Continuity
< 10 Ω (with audible feedback)
7.3.6
Diode measurement (CH1)
Property
Value/range
Measurement current
2 mA
No-load voltage
≤ 5 V
Maximum diode voltage
4 V
Robert Bosch GmbH
Technical Data | KTS 560 / 590 (KTS 5a Series) | 25 |
Value/range
10 Hz — 100 kHz (-3 dB)
200 mV — 30 V
±2 % of measurement value, ad-
ditional
±0.5 % of measurement range
100 µV — 100 mV
(depending on measuring
range)
7.4
Oscilloscope specifications
Measurement channel 1 (CH1)
Measurement channel 2 (CH2)
Input resistance > 900 kohms.
Property
Value/range
Measuring range
200 mV — 60 VDC, 30 VAC,
42 VACpeak
Coupling
DC, AC,
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
Signal source
CH1/CH2: U, 100 A, 600 A,
Diagnosis pins 1 to 15 (not pins 4, 5)
X-deflection
25 µs — 1 s
Trigger mode
Manual, Auto-Time, Auto-Level
Trigger source
CH1, CH2
Pretrigger time
0 % — 100 %
Frequency range
> 1 MHz (typical 5 MHz)
Bandwidth
4 MHz (with measuring lead)
Resolution
12 bits at 1 MS/s /
1)
8 bits at 20 MS/s
Sampling rate
20 MS/s
1)
Memory depth per
50 signal curves
channel
with 512 – 2560 coordinates
MS = Megasamples
1)
7.5

Power supply unit

Property
Input voltage
Input frequency
Output voltage
Output current
Operating temperature
7.6
Bluetooth Class 1
Wireless connection
KTS 560 / 590 to PC/Laptop
Workshop environment in the open
space
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
en
floating
floating
Value/range
100 VAC— 240 VAC
47 Hz — 63 Hz
15 V
1.66 A
0 °C — 40 °C
Minimum range
30 meters
10 meters
|
1 689 989 223
2016-07-20

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kts 590Kts 5a series

Inhaltsverzeichnis