5. Repair

5.1 Setting the mains voltage on the
power pack / power supply unit
for the RTM 430
54
Before operating the power supply unit, please check that the voltage set on the power
pack / power supply unit corresponds to the lighting-circuit mains voltage. Readjust if
necessary.
Electric-shock hazard!
Only authorized servicing technicians may set the mains voltage on the power
supply unit! The power pack / power supply unit must have been disconnected
from the mains power supply before doing this!
– Remove the housing cover.
– Attach the connecting leads on the transformer to the correct voltage input on the
transformer (see illustration).
Possible settings:
230 V (factory setting)
250 V, 100 V, 110 V, 127 V
– Replace the mains fuse by the supplied fuse (4 A, slow-blow).
– Close the housing cover.
– Conduct the safety test as specified by local regulations (e.g. in accordance with VDE
in Germany).
Mains voltage
230 V
230 V
X
250 V
X
127 V
110 V
X
100 V
! The adhesive label specifying the voltage must be replaced if the mains voltage
setting is adjusted. The adhesive label is enclosed with the RTM 430.
459591Ha
Transformer connection
110 V
- 15 %
+ 15%
X
X
X
X
X
230 V
110 V
-15%
0 V
+15%
0 V
X
X