Device is not building up pressure
– Nozzle is set to "CHEM"
Set nozzle to "High pressure".
– Nozzle is blocked/ washed out
Clean/ replace nozzle.
– Sieve in the water connection is dirty
Clean sieve.
– Sieb in front of the water scarcity safe-
guard is dirty.
Clean sieve.
– Amount of water supply is too low.
Check water supply level (refer to tech-
nical data).
– Detergent tank is empty.
Top up detergent orset dosing value for
detergent to "0".
– Detergent dosing valve is leaky.
Check dosing valve.
– Safety valve is displaced.
Adjust safety valve (Customer Service).
– Safety valve is leaky.
Replace the safety valve and/or the
washer (Customer Service).
– Overflow valve is defective
Replace overflow valve (Customer Ser-
vice).
– Air within the system
Vent pump:
Set dosing value for detergent to "0".
Open the water supply.
Start the engine according to the oper-
ating instructions of the engine manu-
facturer.
To dearate the appliance, unscrew the
nozzle and allow the appliance to run
until the water exits in a bubble-free
state.
Switch off the appliance and fit the noz-
zle again.
Water jet is not uniform
– Nozzle is blocked.
Clean the nozzle.
– Safety valve is displaced.
Adjust safety valve (Customer Service).
Device is not sucking in detergent
– Nozzle is set to "High pressure"
Set nozzle to "CHEM".
– Detergent suction hose with filter is
leaky or blocked
Check/ clean detergent suction hose
with filter.
Oil in the high pressure pump is
– Washer is defective.
Inform Customer Service.
Burner does not start
– Temperature limiter has got triggered
again.
Get the device checked by Customer
Service.
– Fuel tank empty
Refill.
– Water shortage
Check water supply, check connec-
tions, clean water shortage safeguard.
– Fuel pump is defective
Replace fuel pump (Customer Service).
– Fuel filter dirty
Change fuel filter.
– No ignition spark
If device is in use and no ignition spark can
be seen through the viewing glass, have
device checked by customer service.
– Uneven spraying of fuel at the burner
nozzle
Clean fuel filter.
Water scarcity safeguard does not
switch on - no flame
– Water inlet is closed.
Open the water supply.
– Amount of water supply is too low.
Increase water flow quantity.
– Sieve blocked in the water shortage
safe guard.
Clean sieve in the water shortage safe
guard.
– Valves in the high pressure pump are
leaky or dirty.
Inform Customer Service.
– 9
EN
milky
23