Safety valve is displaced.
Adjust safety valve (Customer Service).
Safety valve is leaky.
Replace the safety valve and/or the
washer (Customer Service).
Overflow valve is defective
Replace overflow valve (Customer
Service).
Air within the system
Vent pump:
Set dosing value for detergent to "0".
Open the water supply.
Start the engine according to the oper-
ating instructions of the engine manu-
facturer.
To dearate the appliance, unscrew the
nozzle and allow the appliance to run until
the water exits in a bubble-free state.
Switch off the appliance and fit the noz-
zle again.
Water jet is not uniform
Nozzle is blocked.
Clean the nozzle.
Safety valve is displaced.
Adjust safety valve (Customer Service).

Device is not sucking in detergent

Nozzle is set to "High pressure"
Set nozzle to "CHEM".
Detergent suction hose with filter is
leaky or blocked
Check/ clean detergent suction hose
with filter.
Oil in the high pressure pump is
Washer is defective.
Inform Customer Service.
Burner does not start
Temperature limiter has got triggered
again.
Get the device checked by Customer
Service.
Fuel tank empty
Refill.
24
milky
Water shortage
Check water supply, check connec-
tions, clean water shortage safeguard.
Fuel pump is defective
Replace fuel pump (Customer Service).
Fuel filter dirty
Change fuel filter.
No ignition spark
If device is in use and no ignition spark can
be seen through the viewing glas, have de-
vice checked by customer service.
Uneven spraying of fuel at the burner
nozzle
Clean fuel filter.
Water scarcity safeguard does not
switch on - no flame
Water inlet is closed.
Open the water supply.
Amount of water supply is too low.
Increase water flow quantity.
Sieve blocked in the water shortage
safe guard.
Clean sieve in the water shortage safe
guard.
Valves in the high pressure pump are
leaky or dirty.
Inform Customer Service.
If malfunction can not be fixed, the device
must be checked by customer service.
– 10