Pressure Does Not Build Up In The Appliance - Kärcher K 6.610 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für K 6.610:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pressure does not build up in
the appliance
Check setting at the spray lance.
Appliance ventilation.
Switch on the appliance without
connection the high-pressure hose
(max. 2 minutes) and run it until the
water discharging from the high-
pressure outlet is free of bubbles.
Switch off appliance and reconnect
high-pressure hose.
Check the water supply.
Pull out the sieve in the water con-
nection using flat-nose pliers and
clean under running water.
Appliance does not start,
motor hums
Voltage reduction due to weak mains
supply or when using an extension ca-
ble.
When switching on, first pull the le-
ver of the trigger gun and then
switch the appliance switch to "I/
ON".
Strong pressure fluctuations
Clean high-pressure nozzle: Re-
move dirt and debris from the noz-
zle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance
pump is normal. If the leakage in-
creases contact the authorized cus-
tomer service.
26
No detergent infeed
Use spray lance with pressure reg-
ulation (Vario Power).
Turn the spray lance to "Mix" posi-
tion.
Check the settings at the dosage
regulator for detergent.
Check the detergent suction hose
for kinks.
– 14
EN

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

K 7.750K 6.600K 6.750K 7.700K 7.710