Herunterladen Inhalt Inhalt Diese Seite drucken

Pressure Does Not Build Up In The Appliance; Ec Declaration Of Conformity - Kärcher K 6.600 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für K 6.600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pressure does not build up in the
appliance
 Check setting at the spray lance.
 Appliance ventilation.
Switch on the appliance without con-
nection the high-pressure hose (max. 2
minutes) and run it until the water dis-
charging from the high-pressure outlet
is free of bubbles. Switch off appliance
and reconnect high-pressure hose.
 Check the water supply.
 Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Appliance does not start, motor
Cause: Voltage reduction due to weak
mains supply or when using an extension
cable.
 When switching on, first pull the lever of
the trigger gun and then switch the ap-
pliance switch to "I/ON".
Strong pressure fluctuations
 Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
 Check water flow quantity.
Appliance is leaking
 Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.
No detergent infeed
 Use spray lance with pressure regula-
tion (Vario Power).
Turn the spray lance to "Mix" position.
 Check the settings at the dosage regu-
lator for detergent.
 Check the detergent suction hose for
kinks.
22
hums

EC Declaration of Conformity

We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
Product:
Type:
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2004/108/EC
2000/14/EC
2011/65/EC
Applied harmonized standards
EN 50581
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 1997+A1: 2001+A2: 2008
EN 60335–1
EN 60335–2–79
EN 61000–3–2: 2006+A1: 2009+A2: 2009
EN 61000–3–3: 2008
EN 62233: 2008
Applied conformity evaluation method
2000/14/EC: Appendix V
Sound power level dB(A)
Measured:
Guaranteed:
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
CEO
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2013/01/01
– 12
EN
High pressure cleaner
1.167-xxx; 1.168-xxx
1.167-xxx 1.168-xxx
90
93
Head of Approbation
92
95

Quicklinks ausblenden: