Error description
and then stops
Table moves slowly
6.2.2 Table of error messages: Click codes of the
controller
Number of click-
clacks
1x
1x
1x
1x
3x
7x
7x
Error rectification
and the controller. Restore the connections.
Drive is defective: Contact Customer
Service.
The table is located below the safety stop
(downwards travel - slow; upwards travel -
normal speed): Move upwards out of this
area.
Check the load on the table. Reduce the
weight on the table.
When
Status information
When connecting to
Normal operation: The
the power
system operates without a
problem.
Incorrect operation: The
controller has no firmware: Only
1 click sounds.
Up button pressed
Reset: An initialisation
movement is required.
Lower blockage
Reset: The table has reached
detected
the "Reset" position during the
initialisation movement.
Sensor error
Hardware error: The
controller must be replaced. For
manual switches with display,
"C41" is displayed at the same
time.
Motor cable pulled or
Motor cable missing when
missing
connected to the power supply
or was disconnected during
operation. Connect the missing
motor cable to the controller.
Table moves
Caution!
crookedly
have the same height; ini-
tialisation run required.
6 Errors and malfunctions
The drives do not
EN
53