Power Safe (Max Current Switching )
● T his function limit the maximum current during the operation of Air conditioner so it will help to
avoid breaker trips if maximum current reaches to breaker limit. It limits the electrical current during
operation.
NOTE
● O nce Power Safe mode set ,it stored in the memory of remote controller and remain set even after
remote controller reset or battery replacement case.
● P ower Safe mode symbol will be visible in all mode if it set. It is one time setting procedure to use this
function.
● T his function will limits the maximum current drawn by air conditioner by reducing the speed of the
compressor, you may feel less cooling or heating performance compare to normal mode. If you feel so
please cancel Power Safe mode if Power Safe mode is set.
● A t heating operation or Cooling operation during Power Safe setting maximum capacity will decrease.
● D uring Power Safe setting mode , it is recommended to use Auto Fan speed.
When Power Safe set , Maximum current limit for model changes as below.
Type
Model
1.8~3.5kW
Single
5.0kW
Multi
10kW
How to set Power Safe mode (Power Safe)
● P lace the indoor unit in the standby mode ( OFF mode on the
display of remote controller)
● P ress temperature down button
START
about 3 seconds together with directing remote control
toward indoor unit.
●
symbol will be visible on LCD screen and indoor unit will accept
by buzzer sound.
How to cancel Power Safe mode
● P lace the indoor unit in the standby mode ( OFF mode on the
display of remote controller)
● P ress temperature down button
CANCEL
about 3 seconds together.
●
symbol will be disappear on LCD screen and indoor unit will
accept by buzzer sound.
- 22 -
Maximum current with Power Safe
setting
7.0A
10.5A
11.5A(for Operation of 1 indoor unit)
14.0A(for Operation of 2 indoor units)
16.5A(for Operation of 3 indoor units)
16.5A(for Operation of 4 indoor units)
16.5A(for Operation of 5 indoor units)
and Up/Down swing button