Mould Guard Function 2.0 Operation (For single model connection)
 Mould Guard Function 2.0 will be operated not only immediately after stopping operation but also during
stop conditions, if room temperature and ambient temperature will match the condition after some hours'
condition of high humidity.
- Mould Guard Function 2.0 Operation period is about 120 minutes.
- It can't remove Mould or sterilize.
The Process of Mould Guard Function 2.0
Cooling or Dehumidify
operation
Running
● "
" Lamp on the indoor unit lights up during Mould Guard Function 2.0 operation.
● I f the air conditioner is operated in cooling or drying mode, including in auto mode, for more than 10
minutes and then put into off mode, the Mould Guard Function 2.0 operation will start.
● R oom temperature or humidity may rise.
NOTE
If operation of Unit is stopped by Off Timer , the Mould Guard Function 2.0 will not operate
If On Timer is set and on time is within about 2 hours, the Mould Guard Function 2.0 will not operate.
Depending on situation, Mould Guard Function 2.0 will operate with Fan Mode.
Room temperature or humidity may rise during Mould Guard Function 2.0 operation
When there would be the window near indoor unit, the water might condense on the window during
Mould Guard Function 2.0. If necessary, to cancel Mould Guard Function 2.0.
More than 10 min.
Mould Guard Function 2.0
Stop The upper and lower deflector(s) remain open
How to set and cancel Mould Guard Function 2.0
For setting
 P ress the room temperature Up button
1
for 3 seconds together while remote controller in OFF mode with
directing remote control towards indoor unit.
"
" is displayed on the LCD.
For cancelling
 P ress the room temperature Up button
for 3 seconds together while remote controller in OFF mode with
directing remote control towards indoor unit.
2
"
" is disappear on the LCD.
 Once Mould Guard Function 2.0 set, Mould Guard Function 2.0 icon
will always display on the LCD. And it stored in the memory of remote
controller and remain set even after reset or battery replacement case.
It is one time setting procedure to use this function.
How to stop at middle point of Mould Guard Function 2.0 operation
 Press the
button (On/Off) twice, the operation will stop.
3
 "
" Lamp on the indoor unit turns off. But setting for Mould Guard
Function 2.0 will not cancel, it will stop operation only.
- 16 -
About 120 min.
and On Timer
and On Timer