Herunterladen Diese Seite drucken

Hitachi RC-BGH1FA0G Bedienungsanleitung Seite 15

Rak-xj-q-r-hae serie, rak-xj-q-r-hbe serie, rak-vj-phat serie, rai-vj-qhae serie, rai-vj-rhae serie
FrostWash operation for outdoor unit (For single model connection)
● D ust and dirt are being removed by freezing and thawing on the heat exchanger. Outdoor FrostWash
function operates when the outdoor remperature is between 5°C ~ 25°C and indoor room temperature
5°C ~ 25°C
● O utdoor FrostWash operation will operate automatically (accumulated operation or standby time reaches
60 days).
● D uring operation of outdoor frostwash, a bit of condensation on the base pan surface of the outdoor unit is
normal.
FrostWash for outdoor unit (Auto mode)
About 1 min
About 3 mins
Waiting for the
Indoor and outdoor
outdoow fan to
temperature detection
stop
● F rostWash LED lamp on the indoor unit lights up during Outdoor FrostWash operation.
● I f user wishes to stop FrostWash operation, press the
● A fter operating for about 10 minutes or more and on every stop, the fan in outdoor unit rotates in reverse
direction for about 3 minutes each time to remove dust from the heat exchanger.
● D uring Outdoor FrostWash, the entire of heat exchanger freezes. After that, it will thaw to wash away dirt
from the heat exchanger.
● D o not bring hair or tiny rope close to the outdoor unit when the fan of outdoor unit is rotating in reverse
direction.
Outdoor FrostWash auto start conditions
● I f the conditions are not met, Outdoor FrostWash will restart on the next day at the same time.
● I f user stops or cancels during Outdoor FrostWash process, auto Outdoor FrostWash will start after 60
days has passed.
● I f timing for auto Indoor FrostWash and Outdoor FrostWash are overlapped, Indoor FrostWash executed
first.
● D epending on the environment, the heat exchanger may not freeze.
● I n order to protect the machine if there is a strong wind outside the Outdoor FrostWash operation does not
start.
The Process of Outdoor FrostWash
Outdoor FrostWash starts
About 30 mins
It depends on outdoor temperature
Freezing and thawing heat exchanger
The horizontal deflector in the indoor unit
remains open during freezing and thawing
60 days after last Outdoor FrostWash Operation
Indoor temperature and outdoor temperature fulfills the condition
- 15 -
Outdoor FrostWash ends
30 mins
Drying
(On/Off) button
Auto Stop