Connection of semiconductor outputs and analogue inputs

4 semiconductor outputs, aktive HIGH, 12 V DC / 50 mA
AO1: Door break up door 1 or door 2
AO2: Holdup door 1 or door 2
AO3: Tamper reader door 1, door 2 or tamper input AI3
AO4: Mains or battery fault
0 V
4 analogue inputs
AI1 (Door 1)
0 V
AI (Door 2)
2
0 V
AI3 (Tamper)
0 V
AI4 (unused)
0 V
All 4 inputs must be
terminated with 12k1.
The DS push button must be connected behind the monitoring contact, because a
short circuit (push button pressed) may not be effective with the door open.
10.4

Connection of door strikes

Rel2
CC
NOC
NCC
Rel1
CC
NOC
NCC
+12 V DC
U_ext. 1
0 V
+12 V DC
U_ext. 2
0 V
external user
(
fuse
0.5 AF per output)
Door 1
DS push button (PB) and DS monitoring cont. (DS-MC)
AI1
DS-MC
PB
0 V
Door 2 only Two Door Unit
(
AI2
DS-MC
PB
0 V
Load current Ds
No-load current Ds
Door strike 2 (only Two Door Unit)
Load current Ds
No-load current Ds
Door strike 1
Mounting and Connection Instructions AXS4Secure
signal is a 5 second pulse.
signal is a 5 second pulse.
signal static active as long as the event is present.
signal static active as long as the event is present.
(signal mains fault 20 sec. delayed)
Tamper
12k1
)
12k1
If a distributor with cover contact is used, this
must be connected in series with the panel
cover contact.
to analogue input AI2 (see above)
The monitoring contact is closed when the door is closed
to analogue input AI1 (see above)
The monitoring contact is closed when the door is closed
Panel cover contact (PCC)
AI3
PCC
0 V
Connection when installed with an
additional tear-off protection (To-P):
AI3
To-P
PCC
0 V
12k1
12k1