Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions Mains/charger unit 12 V DC / 52 Ah
8.

Connection diagram

The digital input SE (LOW active) can be freely used when operating in "Bus operation mode MB-Secure".
Tamper
1
ST1
(Cover contact
2
or bridge)
1
SE
S
2
S
3
ST2
+12 V DC/2 A
4
0 V
5
Mains
6
1
+12 V DC*
A B C
2
0 V
BUS-2
B*
3
BUS-2/A
4
ST3
MB-Secure
1
Ext. NTC
ST4
2
NTC1
When using an external
NTC, NTC1 must be
removed!
Accumulator 2
red
black
Elektronic fuses
Accumulator 1
S4
LD4
Electronic fuses:
Take notice of the total current consumption!
4 5 6
JP1
1 2 3
LD1
LD2
LD3
S1
ON
JP2
Functional description of connections SE, S, S,
and Mains see chapter 5.2.
JP3
The lines to the control panel (ST2/3
to 2/6) may not be led out of the
JP4
housing.
(Only possible between 2 housings
JP5
mounted side by side and screwed
together).
JP6
The lines BUS-2 may be led out of
the housing. Note "Installation guide-
lines" chapter 10.
black
red
S2
F3
S3
F2
S5
S6
S7
LD5
LD6
LD7
ST5
+ - + - + -
Ext.1 Ext.2 Ext.3
2 A
1 A
1 A
110 V AC / 230 V AC
External user
U_ext. 3 x 12 V DC
for in-plant usage
only
F1
N
L
Mains
LED indication
:
LD1
yellow
Mains missing
1)
LD2
yellow
Fault
LD3
green
- on:
+12 V DC ok
- flashes: electronic fuse triggered
1)
MB-Panel Mode:
- C
ollective fault
(see 7.2)
Bus operation mode MB-Secure:
- Fault, message via BUS-2
Fine-wire fuses:
F1
Primary mains
F2 Accum. 1 charging
F3 Accum. 2 charging
Electronic fuses
:
Function indication via LD4 to LD7, yellow
- off:
+12 V DC ok
- on:
fuse triggered
To reset a triggered fuse, press the according key.
+12 V DC Plug
LED
U_ext. 1
ST5/1
LD4
U_ext. 2
ST5/3
LD5
U_ext. 3
ST5/5
LD6
Output
panel
ST2/4
LD7
Connection +12 V DC* and B* (ST3/1 + 3/3):
Do not connect these two pins to the panel
board, if the ST2 is used for power supply of
the panel.
Keys:
(S2 and S3 for test purposes without mains)
S2 Accumulator voltage ON
S3 Accumulator voltage OFF
Set operating mode with jumpers:
Basic setting: (irrespective of the operating mode)
- JP5 B-C set
- JP3, JP4, JP6 not set
MB-Panel Mode:
- JP2 not set
Bus operation mode MB-Secure:
- JP2 set
7
T4AH250V
4 AF
4 AF
Key
S4
S5
S6
S7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis