Mounting and Connection Instructions AXS4Secure
14.
Technical Data
Rated operating voltage
Operating voltage range
Current consumption at rated voltage:
-
no-load current, inputs open
-
Ethernet operation (additional)
-
per input connection with 12.1 kΩ closed
-
per relay
4 analogue inputs:
-
Voltage
-
End-of-line resistor
-
Monitoring range
4 semiconductor outputs
2 relay outputs
Environmental class according to VdS
Environmental class according to EN 50131-1
Protection class as per EN 60529
Operating temperature range
Storage temperature range
Relative humidity
Weight
Dimensions ZG10 (W x H x D)
Colour
For the Technical data of the power supply, please note the enclosed instructions of the mains/charger
unit.
12 V DC
10.5 V to 15 V DC
200 mA
30 mA
1 mA
45 mA
8 V DC, stabilized
12k1
±40%
aktive HIGH, 12 V DC / 50 mA
Changeover contacts, potential free
- Switching capacity:
max. 8 A / 250 V AC, 5 A / 30 V DC
min. 10 mA / 5 V DC
II
Class II
IP30
- 5 EC to +45 EC
-25 EC to +70 EC
max. 75% non-condensing
4 kg
310 x 340 x 81.5 mm
traffic white (similar to RAL 9016)
39