Checking the ADC settings
To verify the desired settings of the ADC, use the command:
TEST ADC #1513
To use the analogue input for the temperature sensor, use the command:
SET ADCMODE TEMP #1513
Then the temperature sensor (e.g. Conrad item no. 198896) is assessed accordingly at the
analogue input.
To switch off the temperature measurement at the analogue input (ADC) and to reset to voltage
measurement, the following command must be sent:
SET ADCMODE VOLT #1513
To verify the present settings, use the command:
TEST ADCMODE #1513
ADC in temperature mode
The temperature range of the sensor ranges from -40 °C to +125 °C. If no sensor is connected,
"-40°C" is output. You can set a MAX and MIN temperature value the temperature sensor. if
the MIN value is undercut or the MAX value exceeded, an alarm message is sent total stored
phone numbers and the email.
Use the following command for setting:
SET TEMPERATURE <temp1> <temp2> #1513
Temp1 = upper threshold
Temp2 = lower threshold
The value of "Temp1" must exceed "Temp2"!
Example:
SET TEMPERATURE +250 -050 #1513