12. Interface Commands

This is an autonomously working alarm messaging device.
Wrong settings or connections may cause undesired text messages to be sent!
Never enter the phone number that belongs to the SIM card that is inserted in the
module!
Also never enter any phone numbers from any other "GX107" or reporting devices.

12.1 Switching Outputs On/Off (OUT1, OUT2)

These are the two outputs OUT1 and OUT2 that can be switched on and off by sending a text
message to the module. A relay is already connected to the output OUT1.
Output OUT2 is a switching transistor structure as an "open collector". It can be directly
connected by a relay (e.g. Conrad item no. 502892).
To switch on output 1 OUT1, use the command:
SET OUT1 #1513
To switch off output 1 OUT1, use the command:
RESET OUT1 #1513
To switch on output 2 OUT2, use the command:
SET OUT2 #1513
To switch off output 2 OUT2, use the command:
RESET OUT2 #1513
When using a voltage in excess of 25 V/AC or 60 V/DC, the installation must only
be performed by the corresponding specialist.
Power down the device before opening the casing lid!