Operation: Standard operating modes

Standard operating modes

Risk of water damage!
In case of heavy condensation, water can leak out of the air duct system which can lead to
water damage.
The unit comes with three standard operating modes:
Decide which of the three standard operating modes you want your unit to run in and adjust
the settings as desired using the Dantherm PC Tool, the Dantherm ResidentialApp or the
HRC 4 remote control. Note, however, that mandatory minimum values for air exchange may
apply.
Manual operation
Controlling the fan speed manually. In manual mode, the ventilation unit operates at the
selected fan speed until it is changed manually.
Briefly pressing the fan speed button activates the manual mode. The fan speed is increased
by one level (stage 0–4) each time the button is actuated. After stage 4, the fan speed starts
again at stage 0. The stage of the fan speed is indicated by the fan speed level indication on
the control panel.
If the unit runs at stage 4 (fan boost) or stage 0 (off ) in manual mode,
it will automatically switch to stage 3 (nominal mode) after four hours.
Stage 0 of the fan speed can be locked using the PC Tool. If stage 0 is locked, the fan speed
jumps to stage 1 after stage 4.
When the manual mode is activated, this will be indicated by continuous illumination of the
respective LED.
Automatic opera-
When automatic operation is activated, the unit will automatically adjust the fan speed to a
tion (according to
preset week program.
week program)
You can activate the week program from the unit's control panel, but you cannot select it.
Selecting one of the 11 week programs (10 preset programs + one customisable program
in PC Tool) can only be achieved via the Dantherm app, the HRC 4 remote control or the PC
Tool. For more information on the weekly programmes, please refer to the chapter "Week pro-
grams of the time switch".
Briefly pressing the Week/Auto button activates automatic operation. When a week program
is activated, this will be indicated by continuous illumination of the respective LED.
NOTICE
Never switch off the ventilation unit to save energy. Leave the unit switched on conti-
nuously to prevent the formation of condensate.
Manual operation
Automatic operation (according to week program)
Demand-controlled operation
INFORMATION
9