13. Troubleshooting
Fault
The compressor does
not start.
The compressor
starts but there is no
pressure.
The compressor
starts, pressure is
shown on the pressure
gauge, but the tools
do not start.
Possible cause
Mains voltage is not
available.
Mains voltage is too low.
Outside temperature is
too low.
Motor is overheated.
Non-return valve leaking Replace the non-return valve.
The seals are damaged.
The hose connections
have a leak.
A quick coupling has a
leak.
www.scheppach.com
Remedy
Check the cable, mains plug, fuse
and socket.
Make sure that the extension cable is
not too long. Use an extension cable
with large enough wires.
Never operate with an outside tem-
perature of below +5° C.
Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
Check the seals and have any
damaged seals replaced by a service
centre.
Check the compressed air hose and
tools and replace if necessary.
Check quick coupling, replace if
necessary.