9.5 Using the air blow gun
You can also use the tyre inflation device (G) as an air blow gun to clean out cavities and to
clean soiled surfaces and work equipment.
To do so, please first remove the hose with the valve adapter (8).
Now screw the blow-out adapter (D) to the tyre inflation device (G).
9.6 Using the adapter set
The adapter set enables you to use the following additional capabilities of the tyre inflation
device:
• Pumping up balls with the help of the ball needle (F).
• The valve adapter (E) enables bicycle tyres to be inflated.
• Filling pools, air mattresses or boats with the help of the additional adapter (K).
• Filling items with threaded valves (e.g. boats) with the screw-on valve adapter (J).
• Deflating large volume items. The deflating adapter (C) can be used for this.
• The two conical universal adapters (A/B) can likewise be used for inflating air mattresses.
10. Electrical connection
The electrical motor installed is connected and ready for operation. The connec-
tion complies with the applicable VDE and DIN provisions. The customer's mains
connection as well as the extension cable used must also comply with these regu-
lations.
When working with spray attachments and during temporary use outdoors, the device must
be connected to a residual current circuit breaker with a trigger current of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is often damaged.
This may have the following causes:
• Pressure points, where connection cables are passed through windows or doors.
• Kinks where the connection cable has been improperly fastened or routed.
• Places where the connection cables have been cut due to being driven over.
• Insulation damage due to being ripped out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used and are life-threatening due
to the insulation damage.
Check the electrical connection cables for damage regularly. Ensure that the connection
cables are disconnected from electrical power when checking for damage.
Electrical connection cables must comply with the applicable VDE and DIN provisions.
Only use connection cables with the designation H05VV-F.
The printing of the type designation on the connection cable is mandatory.