Disinfect the face mask with Curacid PSA Rapid or equivalent. Follow the
3.
instructions supplied with the disinfectant.
. Rinse the face mask thoroughly with clean water.
4
Shake the mask to remove excess water and dry the mask, avoiding direct heat
5.
and sunlight.
Refer to "Extended cleaning and disinfection", available on www.interspiro.com/
support, for removal and cleaning of the exhalation valve on extraordinary occasions
BREATHING VALVE
ATTENTION! WHEN CLEANING THE BREATHING VALVE IT MUST BE COMPLETELY DRY BEFORE IT IS
REASSEMBLED AND PUT BACK INTO SERVICE. REMAINING WATER MIGHT FORM ICE ON VITAL PARTS, RESULTING
IN MALFUNCTION OF THE BREATHING VALVE.
Clean the outside of the breathing valve with a cloth and lukewarm water
1.
(maximum 40° C) with Curacid PSA Rinse or equivalent.
Alternatively the breathing valve can be submerged and cleaned in lukewarm
water (maximum 40° C) with
#31731-51) and breathing hose must be mounted to prevent water from entering
the breathing valve.
Wipe the breathing valve clean with a cloth and clean water. Or rinse the
2.
breathing valve in clean water with the sealing plug and breathing hose mounted.
Dry the breathing valve
3.
Refer to "Extended cleaning and disinfection", available on www.interspiro.com/
support, for disassembling and cleaning of the breathing valve on extraordinary
occasions.
8
STORAGE
Store in a cool, dry and dust-free environment. Protect rubber parts from direct
sunlight, UV radiation and direct heat. When the regulator unit is not connected the
cylinder valve shall always have a protective plug.
During storage, the breathing valve shall be in the position for activated positive
pressure, see section 2.
9
EXTRA AIR CONNECTION
Some models are equipped with an extra air connection which can be used to:
Connect to a chemical suit ventilation system
1.
Connect a rescue hose between two apparatuses
2.
Connect an extra mask
3.
Connect the resuscitation mask Revitox
4.
Feed the apparatus from an external air source
5.
Curacid PSA Rinse