Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for products with a high start-
ing current (from 3000 watts)!
Connection type X
If the mains connection cable of this product is dam-
aged, it must be replaced by a special connection ca-
ble which can be obtained from the manufacturer or its
service department.
• The product fulfils the requirements of EN 61000-
3-11 and is subject to special connection require-
ments. This means that use at any freely selectable
connection points is not permitted.
• Given unfavourable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is only intended for use at connection
points that
a) do not exceed a maximum permissible mains im-
pedance "Z" (Zmax. = 0.418 Ω), or
b) have a mains constant current carrying capacity
of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
14. Cleaning
Danger!
Pull out the battery before carrying out any cleaning
work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub the
product clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the product directly
after every use.
• Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the product. Make sure that no water can
penetrate the interior of the product. Water penetra-
tion increases the risk of an electric shock.
15. Storage
Store the product and its accessories in a dark, dry and
frost-free place that is inaccessible to children.
The optimum storage temperature lies between 5 and
30 ˚C.
Store the product in its original packaging. Cover the
product to protect it from dust or moisture. Store the
operating manual with the product.
16. Maintenance
If specialists for unusual maintenance work or repairs
must be involved, please always contact a service
point recommended by us or contact us directly.
• Only perform repair, maintenance and cleaning work
as well as the correction of malfunctions with the
drive switched off as a basic rule.
• All protective and safety equipment must be reas-
sembled immediately after repair, maintenance is
completed.
16.1 Carbon brushes
If excessive sparks are generated, have an electrician
check the carbon brushes.
m ATTENTION! The carbon brushes must only be re-
placed by an electrician.
16.2 Check the oil level
The oil level must be checked before every use of the
device.
1.
Place the device on the floor with the tool receiver
facing down.
www.scheppach.com